Norstat now carries the ReeR MOSAIC M1 S COM Safety Module, an enhanced master unit that integrates a Fieldbus Interface.
The M1S COM maintains the same functions as the Mosaic M1 & M1S but integrates 2 RJ45 network connectors for Fieldbus and / or remote connection. 4 integrated Fieldbus interface protocols, Ethernet IP, EtherCAT, PROFINET and MODBUS TCP are available and selectable via the MSD configuration software. This enhanced unit is geared toward more complex systems, specifically control of machinery that requires a greater number of safety outputs. This new Fieldbus ready version with its 2 RJ45 Lan connectors allows for interfacing with the main Ethernet Fieldbuses as well as configuration from remote sources.
The MOSAIC M1S COM has 8 digital inputs, 4 single OSSD or 2 pairs of safety outputs, 4 test outputs and up to 4 EDM/RESTART inputs. The M1S COM allows for up to 48 programable status outputs and can handle 128 operators via the MSD software. Communication speed is 10/100 Mbits and connections are via removeable terminal blocks, screw, or clamps